Tim Wilborne
Tim Wilborne
  • Видео 1 014
  • Просмотров 10 802 644
How to Wire 2 Wire vs 4 Wire 4-20mA Devices
Helping you become a better technician so you will always be in demand
Get the full details of this lesson at courses.twcontrols.com/
Items used in this video:
PLC Trainer twcontrols.com/plc-trainers
The above links make these videos possible. Please use them!
Subscribe to our Main channel for How To's ruclips.net/user/TimWilborne
Просмотров: 323

Видео

Write CIP Message Instruction from a Micro850 PLC to another Micro800
Просмотров 5557 часов назад
Helping you become a better technician so you will always be in demand Get the full details of this lesson at twcontrols.com/plc-lessons Items used in this video: PLC Trainer twcontrols.com/plc-trainers Festo Didactic Meclab controls.tw/festo-meclab controls.tw/festo-meclab The above links make these videos possible. Please use them! Subscribe to our Main channel for How To's ruclips.net/user/T...
Troubleshooting Kinetix Servo Programs
Просмотров 63714 часов назад
You will find many PLC programs work when they work and are terrible to troubleshoot when they don't. Helping you become a better technician so you will always be in demand Get the full details of this lesson at twcontrols.com/plc-lessons Items used in this video: PLC Trainer twcontrols.com/plc-trainers The above links make these videos possible. Please use them! Subscribe to our Main channel f...
Duplicate Destructive Bits in PLCs. The BEST Program Scan Lesson.
Просмотров 1,9 тыс.День назад
Helping you become a better technician so you will always be in demand Get the full details of this lesson at courses.twcontrols.com/ Items used in this video: PLC Trainer twcontrols.com/plc-trainers Festo Didactic Meclab controls.tw/festo-meclab controls.tw/festo-meclab The above links make these videos possible. Please use them! Subscribe to our Main channel for How To's ruclips.net/user/TimW...
Adding a Turck IO Link to a Micro800 PLC over Modbus TCP
Просмотров 886День назад
Modbus data addresses can be a little tricky, pay close attention to how we figured out those values. Helping you become a better technician so you will always be in demand Get the full details of this lesson at courses.twcontrols.com/ Items used in this video: PLC Trainer twcontrols.com/plc-trainers The above links make these videos possible. Please use them! Subscribe to our Main channel for ...
CCW. What Does the COP Instruction's Swap Parameter Do?
Просмотров 59114 дней назад
Helping you become a better technician so you will always be in demand Get the full details of this lesson at twcontrols.com/plc-lessons Items used in this video: PLC Trainer twcontrols.com/plc-trainers Festo Didactic Meclab controls.tw/festo-meclab controls.tw/festo-meclab The above links make these videos possible. Please use them! Subscribe to our Main channel for How To's ruclips.net/user/T...
Measuring AC on DC and DC on AC. DON'T Make This Mistake!
Просмотров 1,1 тыс.14 дней назад
An important part of verifying that there is no voltage present before doing work on an electrical system is identifying whether it is AC or DC voltage. Helping you become a better technician so you will always be in demand Get the full details of this lesson at twcontrols.com/plc-lessons Items used in this video: PLC Trainer twcontrols.com/plc-trainers Fluke T6-1000 controls.tw/fluke-t6-1000 F...
Novelty Automation. Unique PLC Arcade in London by Tim Hunkin
Просмотров 72621 день назад
Helping you become a better technician so you will always be in demand Get the full details of this lesson at twcontrols.com/plc-lessons Items used in this video: PLC Trainer twcontrols.com/plc-trainers The above links make these videos possible. Please use them! Subscribe to our Main channel for How To's ruclips.net/user/TimWilborne
Assign IP Address via DHCP, BOOTP, Ethernet/IP, Profinet, and GigE
Просмотров 64321 день назад
Helping you become a better technician so you will always be in demand Get the full details of this lesson at courses.twcontrols.com/ Items used in this video: PLC Trainer twcontrols.com/plc-trainers The above links make these videos possible. Please use them! Subscribe to our Main channel for How To's ruclips.net/user/TimWilborne
Kinetix MAG Motion Axis Gearing in Studio 5000
Просмотров 72221 день назад
You can connect two axis together in a "follower/leader" or "master/slave" configuration where one axis mimics what the other is doing. Helping you become a better technician so you will always be in demand Get the full details of this lesson at twcontrols.com/plc-lessons Items used in this video: PLC Trainer twcontrols.com/plc-trainers The above links make these videos possible. Please use the...
Writing a PLC Program for a Festo MecLab Conveyor
Просмотров 830Месяц назад
Helping you become a better technician so you will always be in demand Get the full details of this lesson at courses.twcontrols.com/ Items used in this video: PLC Trainer twcontrols.com/plc-trainers Festo Didactic Meclab controls.tw/festo-meclab controls.tw/festo-meclab The above links make these videos possible. Please use them! Subscribe to our Main channel for How To's ruclips.net/user/TimW...
Getting Started with your Analog Simulator for 4-20 mA and 0-10 VDC
Просмотров 513Месяц назад
Helping you become a better technician so you will always be in demand Get the full details of this lesson at courses.twcontrols.com/ Items used in this video: PLC Trainer twcontrols.com/plc-trainers The above links make these videos possible. Please use them! Subscribe to our Main channel for How To's ruclips.net/user/TimWilborne
Getting Started with your RTD Temperature Simulator
Просмотров 545Месяц назад
Getting Started with your RTD Temperature Simulator
Do You Really Need a Fluke Multimeter?
Просмотров 1,3 тыс.Месяц назад
All Multimeters are NOT the same. But is Fluke really better? Helping you become a better technician so you will always be in demand Get the full details of this lesson at twcontrols.com/plc-lessons Items used in this video: PLC Trainer twcontrols.com/plc-trainers Fluke T6-1000 controls.tw/fluke-t6-1000 Fluke 87V controls.tw/fluke-87V Fluke 28II controls.tw/fluke-28ii Fluke PRV240FS controls.tw...
Adding a Turck IO Link Ethernet Module to a Micro850 or Micro870 PLC
Просмотров 874Месяц назад
Adding a Turck IO Link Ethernet Module to a Micro850 or Micro870 PLC
What Automation Products Should We Look for at Automate Show?
Просмотров 721Месяц назад
What Automation Products Should We Look for at Automate Show?
Communications Resource Has Been Locked by Another CCW Instance
Просмотров 659Месяц назад
Communications Resource Has Been Locked by Another CCW Instance
Getting Started with Your Servo / Encoder Simulator
Просмотров 7942 месяца назад
Getting Started with Your Servo / Encoder Simulator
Micro850 Encoder High Speed Counter Configuration
Просмотров 9272 месяца назад
Micro850 Encoder High Speed Counter Configuration
Studio 5000 Find and Replace for Copying and Pasting Code
Просмотров 9132 месяца назад
Studio 5000 Find and Replace for Copying and Pasting Code
Troubleshooting RTD Inputs in Connected Components Workbench
Просмотров 7792 месяца назад
Troubleshooting RTD Inputs in Connected Components Workbench
Top 10 OSHA Workplace Violations and History of Protecting Workers
Просмотров 4942 месяца назад
Top 10 OSHA Workplace Violations and History of Protecting Workers
Wire Your Festo MecLab Conveyor to a Micro850 PLC Trainer
Просмотров 8732 месяца назад
Wire Your Festo MecLab Conveyor to a Micro850 PLC Trainer
What CAT Rating Do You Need in a Multimeter?
Просмотров 8642 месяца назад
What CAT Rating Do You Need in a Multimeter?
Testing a 4-20mA Sensor. DON'T Short Your PLC Input to 24VDC!
Просмотров 2,1 тыс.2 месяца назад
Testing a 4-20mA Sensor. DON'T Short Your PLC Input to 24VDC!
RTD Temperature Simulator for P100 - 2, 3, or 4 Wire
Просмотров 6452 месяца назад
RTD Temperature Simulator for P100 - 2, 3, or 4 Wire
Cutting and Stripping Wire Fast
Просмотров 1,2 тыс.2 месяца назад
Cutting and Stripping Wire Fast
Read Message Data from Micro850 to Micro850 PLC
Просмотров 1,2 тыс.2 месяца назад
Read Message Data from Micro850 to Micro850 PLC
3 Tips for Getting Started with Your IO Link Sensor Trainer
Просмотров 1,4 тыс.3 месяца назад
3 Tips for Getting Started with Your IO Link Sensor Trainer
Simulate Encoder and Servo Signals for Motion Control
Просмотров 8343 месяца назад
Simulate Encoder and Servo Signals for Motion Control

Комментарии

  • @DakotaAntczak
    @DakotaAntczak 10 часов назад

    do you know where I could find the schematics to this like the wiring diagram/pnumatic diagram/how to assemble it. when it comes to learning having physical documentation to mark up really would help

    • @TimWilborne
      @TimWilborne 6 часов назад

      You can find them in the Festo curriculum. I talk about how I wired mine in this video. ruclips.net/video/eqwZvAop6L0/видео.html

  • @fethilakhdari1078
    @fethilakhdari1078 14 часов назад

    Thank Tim, for a good presentation, I am somewhat puzzled by the apparent dissimilarity between the content and the title of this video. The title says "Do Motion with the Micro820 PTO Pulse Train Output Instruction", but the content shows a PWM instruction rather than a PTO instruction. Am I missing something here? Thank you again for a good video. Fethi Lakhdari.

    • @TimWilborne
      @TimWilborne 4 часа назад

      It has to do with the more common question. People usually ask, what can you do with the Micro820s PTO output since they saw it in the specifications They don't yet know what a PWM is. Also, when people think PWM, they usually think some type of motion control such as step and direction. The Micro820 can't do that. Here's a video on the Micro850's PWM being used for motion control. ruclips.net/video/rMVIuYhvr9g/видео.html

  • @jerson8146
    @jerson8146 День назад

    hi new subscriber here.. . just want to ask what does "no safety signature" mean on Allen bradley PLC

    • @TimWilborne
      @TimWilborne День назад

      That means someone didn't complete the safety checklist

    • @jerson8146
      @jerson8146 День назад

      @@TimWilborne Thanks for the quick reply.. So how to fix that?

    • @jerson8146
      @jerson8146 День назад

      What should i do next.?. im using 5069-l320erms3 controller.. Thanks in advance

    • @TimWilborne
      @TimWilborne 4 часа назад

      The answer to that's way too complicated for a RUclips comment. You need to look at one of the safety certifications such as TUV Rhineland.

  • @tedferrell8544
    @tedferrell8544 День назад

    Tim- DNP3 on the micro 870 has a store and forward capability. I was reading somewhere that the OPCUA, like what rolled out with the v36 studio in the 5380 and 5580 controller can native standup opcua server and client. and this article indicated it had store and forward capabilities. have you messed with this?

    • @TimWilborne
      @TimWilborne День назад

      I have read about it about but haven't played with it yet

  • @jeffnery8454
    @jeffnery8454 День назад

    Good morning Tim, would you like to teach how to configure the ADC mode on the E-300 Relay. ?

    • @TimWilborne
      @TimWilborne День назад

      No, I've never played with the ADC on it.

  • @dagryl
    @dagryl День назад

    It doesn't change anything in terms of IEC 61131-3, I can't think of an easier conversion than changing the mnemonic to be compatible with the norm. If Rockwell wants to be compatible with IEC 61131-3, it should redesign the project structure and instructions implementations like TIMER or COUNTER.

    • @TimWilborne
      @TimWilborne День назад

      They are making steps in the right direction. Some users are very upset about the changes, others welcome them.

  • @ricamonta899
    @ricamonta899 День назад

    Hi, do you have any videos on AB E300 ( ethernet) setting up the inputs and relays?

    • @TimWilborne
      @TimWilborne День назад

      No, I should pick one up sometime. I have worked with them before, very handy for monitoring

    • @ricamonta899
      @ricamonta899 День назад

      @@TimWilborne yes they are. I know the devicenet module with emulate mode,But Ethernet mode, different.

  • @phillipborbon2059
    @phillipborbon2059 2 дня назад

    Well. I am interested. Good videos you have.

  • @tjvaouli5458
    @tjvaouli5458 2 дня назад

    HOw do i make a safety shutdown

    • @TimWilborne
      @TimWilborne 2 дня назад

      Lots of variables to consider. I would look into something such as the TUV Rhineland safety certification

  • @Mooe2
    @Mooe2 2 дня назад

    you're the best please we need extra applications for siemens PLC

    • @TimWilborne
      @TimWilborne 2 дня назад

      We're working on building out a Siemens plus programming series

  • @gibbeys
    @gibbeys 3 дня назад

    I absolutely love your videos. I’ve learned so much from them and the encoder simulator is awesome. The only thing I would add is how to configure additional HSC’s…. That stuff is a little difficult to interpret. I was able to incorporate two HSC’s into my project from what I learned. Thank you!

    • @TimWilborne
      @TimWilborne 3 дня назад

      Yes, I wish the HSC was more intuitive. The issue is that it can be configured for so many different uses that it causes confusion.

  • @sheeshjustchill
    @sheeshjustchill 3 дня назад

    How can I join that classroom sir?

    • @TimWilborne
      @TimWilborne 3 дня назад

      You can learn more at the following link twcontrols.com/plc-lab

  • @user-kq7sg3qp8n
    @user-kq7sg3qp8n 3 дня назад

    Unrelated ,but does anyone have any strong methods/techniques for diagnosing machines that use structured text programming for the plc ? Any resources for diagnosing machines using structured text code ? Thanks

    • @TimWilborne
      @TimWilborne 3 дня назад

      I have been working on improving my structured text skills and should do some videos on it. The biggest thing that people don't realize is what the set of eyeglasses do at the right end of the online bar. They give you current values of the tags in your program.

    • @shivsrikakolum2100
      @shivsrikakolum2100 3 дня назад

      @@TimWilborneyes I wasn’t aware pf that function . Until once I accidentally clicked on it while searching for an alarm active

    • @TimWilborne
      @TimWilborne 4 часа назад

      I think that's how I found it too 😂

  • @Helmet_Tester
    @Helmet_Tester 3 дня назад

    TIM !!! This would have been nice to know a year ago. Was scratching my head and eventually had to do it the hard way. Through Powerflex controls. UGH! Glad you were made aware of issue and made this video for us. No more stress!

  • @dougbaker89
    @dougbaker89 4 дня назад

    Tim, I need help! Trying to connect to a MicroLogix 1100, which I’ve many many times. The IP is 10.218.120.9 I’ve tried Ethernet Ip and Ethernet drivers. Set my computer to manual and Ethernet to 10.218.120. 20 When I configure drivers and choose my Ethernet adapter is doesn’t show the IP address, it shows unknown ? I can’t connect to the 1100 and it won’t ping either. I am using windows 11 I’m lost any suggestions Thanks Doug

    • @TimWilborne
      @TimWilborne 3 дня назад

      If you can't ping it, start with the basics. Here is a video on troubleshooting Ethernet settings ruclips.net/user/liveW7Q5ZgvEWiw?feature=share

  • @mayezdove
    @mayezdove 4 дня назад

    thanks a lot ,,

  • @jaggarhenry6639
    @jaggarhenry6639 4 дня назад

    having trouble converting negative decimal to binary and u helped me in less than 5 minutes, thank u!

  • @susanpokorny8176
    @susanpokorny8176 4 дня назад

    What do you do with the green wire if you have a three wire dryer? Where does it get hooked into?

    • @TimWilborne
      @TimWilborne 4 дня назад

      Check your installation instructions. There will be a designated spot

  • @abdulqodoosalsowail4486
    @abdulqodoosalsowail4486 5 дней назад

    GOLD

  • @JDChaidez
    @JDChaidez 5 дней назад

    Yes Sir! Great Job Tim. I Always Wondered How People Knew Stuff I Didn't! Because of Guys Like You, Now I am Smart! S...M...R...T...Dohh!

  • @a3rstang
    @a3rstang 5 дней назад

    Newish to programming so it had be baffled for a while as to why the yellow light stayed on even though the output bit on the same rung was not green. Then I remembered your previous video about the scan process from top to bottom. Even though the output bit in rung 0 is not green, it does in fact have a 1 in it during that time in the scan. Therefore making the output bit in rung 1 also having a 1, creating a true state on that rung. The green "true" on the bits can be deceiving. Thanks for the videos, have helped a lot in transitioning from maintenance into automation and programming.

    • @TimWilborne
      @TimWilborne 5 дней назад

      That is great to hear. Check out this one I did the other week where I accidentally added a duplicate destructive bit. ruclips.net/video/tyAlwZ6CRY8/видео.html

  • @mayezdove
    @mayezdove 5 дней назад

    i need to copy sofware from AB 810 micro to other one same modle (blanck one)

  • @mayezdove
    @mayezdove 5 дней назад

    i m very happy see you again i know you since 2008 you was teaching logox bro i remmber your voice . but you get little fat hhhhhh. nice to meet u again Mayez from egypt

  • @color200
    @color200 5 дней назад

    How do you connect voltage controller to servo ? which 2 pins ?

  • @brienwilliams4315
    @brienwilliams4315 6 дней назад

    It must be nice to have access to plc program. Working 2nd shift most of the time we don't have access to that. So I always ask the operator what is it not doing, than go to what ever makes it do what ever it was supposed to do. And work back from there.

    • @TimWilborne
      @TimWilborne 6 дней назад

      Yes, sometimes you have to work with what you have. Hopefully they'll get some of your 2nd shift folks some PLC training

  • @MartinScire
    @MartinScire 6 дней назад

    Will you be offering a Kinetix trainer?

    • @TimWilborne
      @TimWilborne 6 дней назад

      We have made a handful of them but have not decided to make a standard product yet. Send an inquiry in and we'll see if it is a fit for you. twcontrols.com/contact

  • @amel3778
    @amel3778 6 дней назад

    great ! Thank you sir

  • @goodatwhatido3597
    @goodatwhatido3597 7 дней назад

    Thank you Sir. Your videos are awesome.

  • @markdaniels5086
    @markdaniels5086 8 дней назад

    I do want to see

  • @soldierboyone
    @soldierboyone 8 дней назад

    I don't see the download link the site is very old

  • @kk-vw2pi
    @kk-vw2pi 8 дней назад

    What is the benefit of it? Is it only used to connect two ends of a wire or does it have another benefit?

    • @TimWilborne
      @TimWilborne 7 дней назад

      Ultimately that is the primary purpose but there can be many added benefits along the way. The biggest one being time savings.

  • @Chiricuazo701
    @Chiricuazo701 8 дней назад

    This is the best method and the only method that should be used!!!!

  • @cincinnatitypewriters
    @cincinnatitypewriters 8 дней назад

    I am so lost... why if number.1 and if number.2? Why not just if number.1? And why is the not number.3 added to each one?

    • @TimWilborne
      @TimWilborne 8 дней назад

      It is the programmer's preference. You'll see all of them out in the field.

  • @EthanHunter025
    @EthanHunter025 8 дней назад

    Hi Tim, At the 4:45-4:50 mark, you mention how the PLC scan still evaluates input6. I’ve asked the same question during a very advanced Rockwell Training Class with a certified Rockwell instructor who said that it does not get evaluated in order to decrease program scan rate times. Is there any sort of official documentation from Rockwell that you could link stating explicitly that the input6 still gets evaluated?

    • @TimWilborne
      @TimWilborne 8 дней назад

      It evaluates it every time. Look at the text view of the ladder and you can see the exact order.

    • @EthanHunter025
      @EthanHunter025 7 дней назад

      ⁠@@TimWilborneis there any documentation that explicitly states that it evaluates every instruction? The ascii text representation of the rung is just another representation of the same rung in ladder. If I had a link to documentation, I’d have something to physically show people when they doubt whether the instruction gets evaluated or if it skips along to writing to the OTE bit location.

    • @TimWilborne
      @TimWilborne 7 дней назад

      Yes it is in many of the software and processor manuals. I'm not near a computer for the rest of the month so can't site a specific link

  • @electric-nl3fs
    @electric-nl3fs 9 дней назад

    Awesome

  • @andremachadopereira8012
    @andremachadopereira8012 9 дней назад

    Your tips are incredible, I learned a lot of things in this video, thank you very much.

  • @sheeshjustchill
    @sheeshjustchill 10 дней назад

    Thank you will be checking out the store soon

  • @fellstar
    @fellstar 10 дней назад

    Hard lesson learned by new engineers the hard way, the world over. Good vid!

    • @TimWilborne
      @TimWilborne 9 дней назад

      Yes it is whipped me many times. And apparently I still don't learn because I recorded the whole series and didn't notice it 😂

  • @muliarahman3583
    @muliarahman3583 10 дней назад

    Great, it's 110 VAC. Here I'm using 220 VAC

    • @TimWilborne
      @TimWilborne 10 дней назад

      👍

    • @muliarahman3583
      @muliarahman3583 10 дней назад

      Has there any videoss been uploaded on this channel that explained about HART and modbus signals?

    • @TimWilborne
      @TimWilborne 9 дней назад

      Here is a playlist including Modbus server and client, Ethernet and RTU. I haven't worked much with HART. ruclips.net/p/PLUi5cdVq3wTCNyXp_W496Z-td2RPm3nES

    • @muliarahman3583
      @muliarahman3583 9 дней назад

      @@TimWilborne wonderful, thanks a lot

    • @TimWilborne
      @TimWilborne 9 дней назад

      You are welcome

  • @AlloyedFrequencies
    @AlloyedFrequencies 10 дней назад

    That’s not a bad price thank you very much

  • @enkienki8202
    @enkienki8202 10 дней назад

    I would not do this, i am correcting what i said below. I have seen this done many times and it works most of the time and then it doesn't. It introduces a bug. I just corrected a long standing problem in one of our programs due to another tech using a duplicate bit. I was warned about this in school to never do this!

  • @enkienki8202
    @enkienki8202 10 дней назад

    I would duplicate an output like that, i have seen this done many times by people who say it is fine and what it does is inserts a bug into your program.

  • @tigerwolf721
    @tigerwolf721 10 дней назад

    can someone tell us the reason behind using a 7 and 10 in the array. what determines the numbers used when creating a dimensional array.

    • @TimWilborne
      @TimWilborne 10 дней назад

      It is determined by the sauce of data you need to store. It can be larger but not smaller.

  • @cobelali
    @cobelali 10 дней назад

    Thank you for the great explanation. Coming from a computer programming background where nothing happens if the trigger to a command is false, I had a hard time dealing with multiple commands controlling an output. To me, if the input to a rung was false, I expected the output to be untouched, but as you mentioned in the video, if the input is false, the controller will explicitly write a zero to the output.

  • @ThetrollISBACK-hv7uv
    @ThetrollISBACK-hv7uv 10 дней назад

    2:55

  • @chazcampos1258
    @chazcampos1258 10 дней назад

    Great realistic video about how to troubleshoot logic!

  • @shawnspencer8766
    @shawnspencer8766 10 дней назад

    Awesome video. This is actually how I set up my first fault handling. Great way to store data.

  • @jeevanjain5688
    @jeevanjain5688 10 дней назад

    Hi sir am using compact logic L18ER it is going in fault mode while switch on off of main supply what may be the issue pls help sir.

    • @TimWilborne
      @TimWilborne 10 дней назад

      Go to communications, go to fault and see what it tells you

    • @jeevanjain5688
      @jeevanjain5688 10 дней назад

      @@TimWilborne power up fault is coming sir how to rectify

    • @TimWilborne
      @TimWilborne 10 дней назад

      That means someone has assigned a power up fault routine and not actually written the code to handle and clear it. Is it empty?

    • @jeevanjain5688
      @jeevanjain5688 10 дней назад

      @@TimWilborne dont more about this sir how to do can u send step sir thrgh watsap